Fill the chiller with coolant

See the chiller operators manual for details

caution:

Using the wrong coolant can cause damage to the system. Refer to torch

coolant requirements in this section for more information.

Do not over fill the coolant tank.

caution:

Do not turn oN the power to the controller until the chiller reservoir has been

filled. when the power to the controller is turned oN the pump automatically

begins pumping. If the reservoir has not been filled, the pump could be

damaged.

caution:

the first time the chiller is operated it should be run overnight in the

standby mode. the compressor crankcase heater will boil off any refrigerant

absorbed in the compressor oil.