Error codes – Hypertherm HPR800XD Auto Gas Rev.2 User Manual

Page 355

Advertising
background image

Appendix B – CnC interfACe protoCol

HPR800XD Auto Gas –

806500

b-21

Error codes

ID

Name

Description

000

NO ERROR

System is ready to run.

009

FLOW SWITCH TEST

When the pump is restarted after a pump timeout (30 minutes

without a start signal) the system will test the flow switch to make

sure there is sufficient flow before firing the torch.

011

NO_ACTIVE_PROCESS

The power supply receives an invalid current setting from a CNC.

012

TEST IN PROGRESS

One of the gas test modes is running.

013

TEST PASSED

The test completed successfully.

014

CUT GAS CHANNEL #1 FAIL

The gas pressure is dropping on channel #1, indicating a leak.

015

CUT GAS CHANNEL #2 FAIL

The gas pressure is dropping on channel #2, indicating a leak.

016

PLASMA RAMP-DOWN FAIL

Pump output has exceeded 200 psi.

017

SHIELD RAMP-DOWN FAIL

Shield pressure did not decrease in the allotted time.

018

PUMP OVER PRESSURE

Pump output has exceeded 13.79 bar (200 psi.)

020

NO PILOT ARC

No current detected from chopper at ignition and before

1-second timeout.

021

NO ARC TRANSFER

No transfer signal detected before 500-msec timeout.

024 Primary

224 Secondary LOST CURRENT CH1

After transfer, lost the chopper current signal.

025 Primary

225 Secondary LOST CURRENT CH2

After transfer, lost the chopper current signal.

026 Primary

226 Secondary LOST TRANSFER

After transfer, lost the transfer signal.

027 Primary

227 Secondary LOST PHASE

When main contactor is engaged, no “phase OK” input.

028 Primary

228 Secondary LOST CURRENT CH3

After transfer, lost the chopper current signal.

030

GAS SYSTEM ERROR

A failure has occurred in the gas system.

031 Primary

231 Secondary START LOST

Start signal was removed before steady-state operation.

032

HOLD TIMEOUT

Hold signal was applied for longer than 60 seconds.

033

PRE CHARGE TIMEOUT

Gas console was not able to charge the gas lines to the correct

pressure.

034 Primary

234 Secondary PRE CHARGE TIMEOUT

Gas console was not able to charge the gas lines to the correct

pressure.

042

LOW NITROGEN PRESSURE

Nitrogen gas pressure under lower limit of 2.07 bar (30 psi) –

cutting, 0.34 bar (5 psi) – marking

044

LOW PLASMA GAS PRESSURE

Gas pressure under lower limit of 0.34 bar (5 psi) – pre-flow

3.45 bar (50 psi) – cutflow (cutting) 0.34 bar (5 psi) – cutflow

(marking).

045

HIGH PLASMA GAS PRESSURE Gas pressure over upper limit of 7.58 bar (110 psi).

046

LOW LINE VOLTAGE

Line voltage is under lower limit of 102 VAC (120 VAC -15%).

047

HIGH LINE VOLTAGE

Line voltage is over upper limit of 138 VAC (120 VAC +15%).

048 Primary

248 Secondary CAN ERROR

An error occurred with the CAN communication system.

050 Primary

250 Secondary START ON AT INIT

Start signal input is active during power-up.

053

LOW SHIELD GAS PRESSURE Gas pressure is under lower limit of 0.14 bar (2 psi).

Advertising