Hypertherm HPR800XD Auto Gas Rev.2 User Manual

Page 357

Advertising
background image

Appendix B – CnC interfACe protoCol

HPR800XD Auto Gas –

806500

b-23

ID

Name

Description

106 Primary

306 Secondary

CURRENT TOO LOW ON LEM

#2

A current less than 10 amps has been detected by current sensor

2.

107 Primary

307 Secondary

CURRENT TOO HIGH ON LEM

#3

A current greater than 35 amps has been detected by current

sensor 3.

108 Primary

308 Secondary TRANSFER AT INIT

The system has detected current on the work lead during

power-up.

109

COOLANT FLOW AT INIT

Coolant flow is greater than 1.14 lpm (0.3 gpm) when pump is

off.

111

COOLANT OVERTEMP AT INIT

Coolant is indicating overtemp during power-up.

116 Primary

316 Secondary WATCHDOG INTERLOCK

CAN communication error.

123

MV 1 ERROR

Motor valve 1 did not move into position within 60 seconds.

124

MV 2 ERROR

Motor valve 2 did not move into position within 60 seconds.

133

UNKNOWN GAS CONSOLE

TYPE

The power supply control board does not recognize the gas

console installed or has not received a CAN message identifying

the type of console installed.

134 Primary

334 Secondary CHOPPER 1 OVERCURRENT

Chopper 1 current feedback has exceeded 160 amps.

138 Primary

338 Secondary CHOPPER 2 OVERCURRENT

Chopper 2 current feedback has exceeded 160 amps.

139

PURGE TIMEOUT ERROR

The purge cycle did not complete within 3 minutes.

140

AUTO GAS PRESSURE

TRANSDUCER #1 ERROR

Faulty transducer or auto gas control PCB

141

AUTO GAS PRESSURE

TRANSDUCER #2 ERROR

Faulty transducer or auto gas control PCB

142

AUTO GAS PRESSURE

TRANSDUCER #3 ERROR

Faulty transducer or auto gas control PCB

143

AUTO GAS PRESSURE

TRANSDUCER #4 ERROR

Faulty transducer or auto gas control PCB

144

MANUAL GAS CONSOLE

INTERNAL FLASH MEMORY

ERROR

Replace manual gas console control PCB

145

AUTOMATIC GAS CONSOLE

INTERNAL FLASH MEMORY

ERROR

Replace auto gas console control PCB

146 Primary

346 Secondary

CHOPPER #3 OVERTEMP AT

INIT

Chopper #3 is indicating over temp during power-up

147 Primary

347 Secondary

CHOPPER #4 OVERTEMP AT

INIT

Chopper #4 is indicating over temp during power-up

151 Primary

351 Secondary SOFTWARE FAIL

Software has detected an incorrect state or condition.

152

INTERNAL FLASH ERROR

DSP memory is not working properly.

153

PS EEPROM ERROR

EEPROM memory on power supply board not working.

154 Primary

354 Secondary CHOPPER 3 OVER CURRENT

Chopper 3 current feedback has exceeded 160 amps

155 Primary

355 Secondary CHOPPER 4 OVER CURRENT

Chopper 4 current feedback has exceeded 160 amps

Advertising