Aluminum, Plasma / n, Shield 200 a – Hypertherm HPR800XD Auto Gas Rev.2 User Manual
Page 204: Metric english, Marking

OperatiOn
4-98
HPR800XD Auto Gas –
806500
Aluminum
N
2
Plasma / N
2
Shield
200 A
220762
220637
220307
220759
220342
220346
Metric
English
Select
Gases
Set
Preflow
Set
Cutflow
Material
thickness
Arc
Voltage
Torch-to-Work
Distance
Cutting
Speed
Initial Pierce
Height
Pierce Delay
Time
Plasma
gas
Shield
gas
Plasma
gas
Shield
gas
Plasma
gas
Shield
gas
mm
Volts
mm
mm/m
mm Factor % Seconds
N
2
N
2
17
43
73
43
8
158
6.4
6000
9.0
140
0.3
10
4750
0.4
12
3500
0.5
15
166
2350
0.6
20
165
1000
0.8
Select
Gases
Set
Preflow
Set
Cutflow
Material
thickness
Arc
Voltage
Torch-to-Work
Distance
Cutting
Speed
Initial Pierce
Height
Pierce Delay
Time
Plasma
gas
Shield
gas
Plasma
gas
Shield
gas
Plasma
gas
Shield
gas
in
Volts
in
ipm
in
Factor % Seconds
N
2
N
2
17
43
73
43
5/16
158
0.25
236
0.35
140
0.3
3/8
200
0.4
1/2
120
0.5
5/8
166
80
0.6
3/4
165
50
0.8
Marking
Flow rates – lpm/scfh
N
2
Preflow
113 / 240
Cutflow
135 / 287
Select
Gases
Set
Preflow
Set
Cutflow
Amperage Torch-to-Work
Distance
Marking
Speed
Arc
Voltage
Amps
mm
in
mm/m
ipm
Volts
N
2
N
2
10
10
10
10
18
2.5
0.10
6350
250
140
Ar
N
2
30
10
30
10
20
3.0
0.12
2540
100
66
220340