Hypertherm HPR800XD Auto Gas Rev.2 User Manual

Page 231

Advertising
background image

Maintenance

HPR800XD Auto Gas –

806500

5-17

Error code troubleshooting – error codes 062 to 067, 265 to 267

Error code

number

Name

Description

corrective action

062

No shield gas

type

Manual gas – The gas

console control board is

not receiving signals from

the gas selector knob.
Auto gas – The selection

console is not receiving

the shield gas type signal.

1. Auto gas – The process parameters may not have been

downloaded. Verify that the process information can be

viewed on the CNC screen.

2. Manual gas – The selector knob (2) may be set between

positions. Reset the knob.

3. Verify that there is power to the console by looking to see

if any LED on any board in the selection console (auto)

or gas console (manual) is illuminated. If no LEDs are

illuminated, verify that the fuse on the power distribution

PCB is in proper working condition.

4. If the problem still exists, replace the control board.

065

Primary

265

Secondary

Chopper 1

overtemp

Chopper 1 has

overheated.

1. Verify that all chopper fans are operating properly.

Spinning fan blades should be difficult to see.

2. Blow dust out of system, especially from fans and heat

sink of chopper.

3. Verify that the voltage on rear side of J3.202, pins 2 and 3

on PCB3, is less than or equal to 2.9 VDC.

4. If the voltage is low, verify correct wiring between chopper

temperature sensor and J3.202 pins 1 and 2.

5. If wiring is good and overtemp error does not clear after

30 minutes of the power supply idling with the fans

running, replace the chopper.

066

Primary

266

Secondary

Chopper 2

overtemp

HPR260XD

HPR400XD

only

Chopper 2 has

overheated.

1. Verify that all chopper fans are operating properly.

Spinning fan blades should be difficult to see.

2. Blow dust out of system, especially from fans and heat

sink of chopper.

3. Verify that the voltage on rear side of J3.202, pins 5 and 6

on PCB3, is less than or equal to 2.9 VDC.

4. If the voltage is low, verify correct wiring between chopper

temperature sensor and J3.202 pins 4 and 5.

5. If wiring is good and overtemp error does not clear after

30 minutes of the power supply idling with the fans

running, replace the chopper.

067

Primary

267

Secondary

Magnetics

overtemp

Power transformer has

overheated.

1. Verify that all the large fans are operating properly.

Spinning fan blades should be difficult to see.

2. Blow dust out of system especially from fans and large

power transformer.

3. Verify that the voltage on the rear side of J3.202

pins 14 and 15, is equal to or less than 3.2 VDC.

4. If voltage is low or near 0 VDC, inspect wiring between

the transformer’s temperature sensor and J3.202 pins 13

and 14. Look for shorts between wires or to ground.

5. If wiring is good, the transformer has overheated. Allow the

power supply to idle with the fans running for a minimum

of 30 minutes to cool the large power transformer.

6. Replace the transformer’s temperature sensor if it is open

or shorted. Replacement kit part number is 228309.