Torch connections, Connect the torch to the torch lead assembly, Torch connections -47 – Hypertherm HPR800XD Auto Gas Rev.2 User Manual

Page 87: Connect the torch to the torch lead assembly -47

Advertising
background image

InstallatIon

HPR800XD Auto Gas –

806500

3-47

torch connections

connect the torch to the torch lead assembly

1. Uncoil the first 2 meters (6.5 ft) of the leads on a flat surface.

2. Hold the torch assembly in place with the spanner wrench (104269) and remove the mounting sleeve from the torch

assembly.

3. Push back the braided cover and slide the sleeve over the leads. Align the torch with the hoses in the lead assembly.

The hoses must not be twisted. They are taped together to help prevent twisting.

4. Connect the coolant return hose (red).

Braided cover

Sleeve

Coolant return hose

H

caution: Never use PtFE

tape on any joint

preparation.