Hypertherm HPR800XD Auto Gas Rev.2 User Manual

Page 48

Advertising
background image

InstallatIon

3-8

HPR800XD Auto Gas –

806500

The following picture shows an example of a cutting table ground bus. The components shown here may differ from your

system.

The following picture shows an example of a gantry ground bus. It is bolted to the gantry, close to the motor. All of the

individual ground cables from the components mounted on the gantry connect to the bus. A single heavy cable then

connects the gantry ground bus to the table ground bus.

1 2 3 4 5 6 7

1

Gantry ground bus

2

Ground rod

3

Plasma system lead (+)

4

Remote high frequency (RHF) console

5

CNC enclosure

6

Torch holder

7

Plasma system chassis

1

2

1

Cable to the cutting table ground bus

2

Ground cables from components on the gantry

Advertising