Appendix B – CnC interfACe protoCol

b-10

HPR800XD Auto Gas –

806500

command table (5 of 14)

ID

command

System

Description

079 GET_PS_INFO

Manual gas system

Auto gas system

Returns pressures, system state, and system error,

space-delimited
Data:

None
Return value:

Plasma cutflow pressure (0044 = 44 psi)

Plasma preflow pressure (0044 = 44 psi)

Shield cutflow pressure (0044 = 44 psi)

Shield preflow pressure (0044 = 44 psi)

Current setpoint (amps)

System state (see table V) (0003 = state 3)

System error (see table IV) (0000 = error 0)

Cut gas 1 pressure (0044 = 44 psi)

Cut gas 2 pressure (0044 = 44 psi)

N

2

Mix inlet pressure (0044 = 44 psi)

Gas2 Mix inlet pressure (0044 = 44 psi)
Note: Cut gas 1, Cut gas 2, N

2

mix inlet, and Gas 2 mix inlet are

not measured in the manual gas console configuration.
Sample:

>079A0<

>079PC0044 PP0042 SC0034 SP0035 CS0040 ST0003

ER0000 CG0000 CG0000 MV0000 MV0000DE<

084 DOWNLOAD_SOFTWARE

Not currently implemented on the

HD4070 or the HPR systems

TBD

Download new firmware to the plasma system.
Data:

TBD
Return value:

1 = packet accepted, 0 = not accepted
Sample:

TBD

085 WAKE

Manual gas system

Auto gas system

This command is used to wake a system and enable its

transmitter to communicate on a multi drop line.
Data:

System ID, which is set by dipswitches on PC board.
Return value:

Echo of the command
Sample:

>0850CD<

>0850CD<

086 SLEEP

Manual gas system

Auto gas system

Tell all systems on the line to disconnect their transmitters
Data:

None
Return value:

None
Sample:

>0869E<

No response