Appendix B – CnC interfACe protoCol

HPR800XD Auto Gas –

806500

b-7

command table (2 of 14)

ID

command

System

Description

028 READ_PLASMA_AMPS

Manual gas system

Auto gas system

Read actual power supply current.
Data:

None
Return value:

Power supply current in amps
Sample:

>0289A<

>02801305E< (130 amps)

058 SET_NOMINAL_AMPS

Auto gas system

Set the power supply current in amps.
Data:

5-260 Amps (Limited to 130 amps on the HPR130)
Return value:

Actual current value set
Sample:

>05813031<

>058013061< (set 130 amps)

064 GAS_PREFLOW_TEST_START

Manual gas system

Auto gas system

Turn on the preflow gases. Not allowed when cutting.
Data:

None
Return value:

1 = accepted, 0 = not accepted
Sample:

>0649A<

>0641CB<

065 GAS_PREFLOW_TEST_STOP

Manual gas system

Auto gas system

Turn off the preflow gases. Not allowed when cutting.
Data:

None
Return value:

1 = accepted, 0 = not accepted
Sample:

>0659B<

>0651CC<

066 GAS_CUTFLOW_TEST_START

Manual gas system

Auto gas system

Turn on the cutflow gases. Not allowed when cutting.
Data:

None
Return value:

1 = accepted, 0 = not accepted
Sample:

>0669C<

>0661CD<

067 GAS_CUTFLOW_TEST_STOP

Manual gas system

Auto gas system

Turn off the cutflow gases. Not allowed when cutting.
Data:

None
Return value:

1 = accepted, 0 = not accepted
Sample:

>0679D<

>0671CE<)