Mild steel underwater cutting, Plasma / air shield 400 a, Metric english – Hypertherm HPR800XD Auto Gas Rev.2 User Manual

Page 166

Advertising
background image

OperatiOn

4-60

HPR800XD Auto Gas –

806500

Mild steel underwater cutting

No more than 75 mm (3 in) below the surface of the water

O

2

Plasma / Air Shield

400 A

Note: Preflow must be on during IHS.

Flow rates – lpm/scfh

O

2

Air

Preflow

0 / 0

190 / 400

Cutflow

66 / 140 137 / 290

Metric

English

Select

Gases

Set

Preflow

Set

Cutflow

Material

thickness

Arc

Voltage

Torch-to-Work

Distance

Cutting

Speed

Initial Pierce

Height

Pierce Delay

Time

Plasma

gas

Shield

gas

Plasma

gas

Shield

gas

Plasma

gas

Shield

gas

mm

Volts

mm

mm/m

mm Factor %

Seconds

O

2

Air

24

50

60

50

16

144

3.6

3398

7.2

200

0.5

20

147

2535

0.7

22

150

3.8

2311

7.6

0.8

25

153

4.0

1997

8.0

0.9

30

155

4.6

1624

9.2

1.1

40

160

1039

11.5

250

1.9

220636

220637

220635

220631

220632

220571

220629

Select

Gases

Set

Preflow

Set

Cutflow

Material

thickness

Arc

Voltage

Torch-to-Work

Distance

Cutting

Speed

Initial Pierce

Height

Pierce Delay

Time

Plasma

gas

Shield

gas

Plasma

gas

Shield

gas

Plasma

gas

Shield

gas

inches

Volts

inches

ipm

inches Factor %

Seconds

O

2

Air

24

50

60

50

5/8

144

0.14

135

0.28

200

0.5

3/4

146

104

0.6

7/8

150

0.15

90

0.30

0.8

1

154

0.16

77

0.32

0.9

1-1/4

156

0.18

59

0.36

1.2

1-1/2

159

43

0.45

250

1.6

1-3/4

162

36

2.5

Advertising