Maintenance

HPR800XD Auto Gas –

806500

5-31

Initial checks

Before trouble-shooting, do a visual check and verify that proper voltages are present at the power source, transformers

and power distribution board.

1. Disconnect line power by turning OFF the main disconnect switch.

2. Remove the power supply’s top panel and 2 side panels.

3. Inspect interior of power supply for discoloration on PC boards, or other apparent damage. If a component or module

is obviously defective, replace it before doing any testing. Refer to the Parts List section to identify parts and part

numbers.

4. If no damage is apparent, connect power to the power supply, and turn ON the main disconnect switch.

5. Measure the voltage between the W, V and U terminals of TB1 located on the right side of the power supply. See

figure on next page. Also refer to the wiring diagram in Section 7, if required. The voltage between any 2 of the 3

terminals should be equal to the supply voltage. If there is a problem at this point, disconnect main power and check

connections, power cable, and fuses at line disconnect switch. Repair or replace any defective component.

DANgER

SHock HAzARD

Always use caution when servicing a power supply when plugged in and the covers are removed.

Dangerous voltages exist within the power supply which could cause injury or death.