Optional command thc interface, Elec sch:hpr800xd power supply w/auto, Hpr pac dry cutting system – Hypertherm HPR800XD Auto Gas Rev.2 User Manual

Page 325: Dipswitch setting example: s301

Advertising
background image

7-29

Interface

CNC

(Customer Supplied)

141030

CONTROL BOARD

S301

1

2

J300

3

4

3 2 1

4

J303B

J303A

CNC Interface Cable

CNC Interface Cable

(Optional Unit)

THC

Command

CNC Interface Cable

Pendant Ext. Cable

(Optional Unit)

Operator

Pendant

Lifter

Torch

(Optional Unit)

Motor Drive Cable

Lifter I/O Interface Cable

J2B

J2A

PLASMA INTERFACE

BOARD

041842

Serial ID

Dipswitch

Jumper Block

Machine Motion

CNC Interface Cable

Command I/O Cable-Second THC

Command I/O Cable-Third THC

Command I/O Cable-Fourth THC

1 2

J104

1 2

J105

Optional Command THC Interface

See Command

THC Manual for

internal Power

Supply wiring

Torch

1 2 3 4 5 6 7 8

ON

HPR PAC

Dry Cutting System

4

3

2

1

1

A

4

3

2

A

B

C

D

B

C

D

Workpiece

Notes:

1) For a single system installation set Serial ID (S301),

Machine Motion (J300), J104 & J105 as shown above.

2) For a two system installation duplicate a second power supply and Command THC

as illustrated for a single system, set Serial ID as shown for the second system.

3) For a three system installation set up as described above, set Serial ID as shown

for the third system.

4) For a four system installation set up as described above, set Serial ID as shown

for the fourth system.

5) All machine interface cables (Pwr. supply-CNC) used for serial communication between

Pwr. supply-CNC will have a common connection node with the CNC.

6) The CNC will need a dedicated I/O port for each Command THC.

7) If a Hypertherm Automation controller is being used, and there are intermittent communication

failures (PS Link Failure), try removing the jumpers on J104 and J105 on the control board,

and the termination jumper (J6 or J8) on the serial isolation board in the controler.

Only remove the termination jumper on the serial isolation board that is connected

to the HPR power supply. See figure on Sheet 19 for details.

Switches 2-8 are in the Off position

Switch 1 is in the On position

Dipswitch

Serial ID

S301

for second system

S301
Dipswitch

Serial ID
for third system

S301
Dipswitch

Serial ID
for fourth system

Dipswitch setting example:

S301

1

ON

4

2 3

7

5 6

8

1 2 3 4 5 6 7 8

ON

1 2 3 4 5 6 7 8

ON

1 2 3 4 5 6 7 8

ON

1 2 3 4 5 6 7 8

ON

ELEC SCH:HPR800XD POWER SUPPLY W/AUTO

D

013381

SHEET 23 OF 24

Advertising