InstallatIon

3-58

HPR800XD Auto Gas –

806500

Custom Coolant mix for cold operating temperatures

10/16/08

Custom Coolant mix for cold operating temperatures

• Ambient temperature below -12° C / 10° F
• Chiller process temperature below 4° C / 39° F

CAUTION

For operating temperatures colder than the temperature stated above, the percentage of propylene

glycol must be increased. Failure to do so could result in a cracked torch head, hoses, or other damage

to the torch coolant system due to freezing.

Use the chart below to determine what percentage of propylene glycol to use in the mixture.

Mix 100% glycol (028873) with the premixed Hypertherm coolant (028872) to increase the percentage of glycol.

The 100% glycol solution can also be mixed with purifi ed water (see the chart below for water purity requirements) to

achieve the required protection from freezing.

Note: The maximum percentage of glycol should never exceed 50%. Increasing the percentage of glycol reduces

the capacity of the cooling system.

Hypertherm pre-mix (028872)

Maximum glycol percentage

0

0

0

0

0

0

0

0

-7

-6

-5

-4

-3

-2

-1

10

20

30

40

0

10

20

30

40

50

60

-57

-51

-46

-40

-34

-29

-23

-18

-12

-7

-1

4

Freezing point

% of propylene glycol

Freezing point of propylene glycol solution Solution

°F

°C

Advertising