Error code troubleshooting – error codes 116 to 133, 316

Error code

number

Name

Description

corrective action

116

Primary

316

Secondary

Watchdog

interlock

An error occurred with

the CAN communication

system.

1. Verify that cable number 5 (power supply-to-gas console

control cable) is not damaged and is properly connected

to PCB3 and the rear of the gas console.

2. Verify that cable number 6 (power supply-to-gas console

power cable) is not damaged and is properly connected

inside the power supply and to the rear of the gas console.

3a. (Manual gas console) Verify that D1 (+5 VDC) and

D2 (+3.3 VDC) are illuminated on PCB2 inside the gas

console. These LEDs indicate power to PCB2.

3b. (Auto gas console) Verify that D17 (+5 VDC) and

D18 (+3.3 VDC) are illuminated on PCB2 inside the gas

console. These LEDs indicate power to PCB2.

4. If power is present at PCB2 and PCB3 and both gas

console cables are good, then PCB2 or PCB3 has failed.

Use the CAN tester to verify which board needs to be

replaced.

5. Verify that the gas console control PCB and power

distribution PCBs are securely mounted to the chassis at

all four corners.

123

MV1 error

Auto gas

only

Motor valve 1 did not

move into position within

60 seconds.

Verify that LED D17 or D18 illuminates on the AC valve driver

PCB in the selection console. If either illuminates, replace the

motor valve. If they do not illuminate, replace PCB3.

124

MV2 error

Auto gas

only

Motor valve 2 did not

move into position within

60 seconds.

Verify that LED D19 or D20 is illuminating on the AC valve

driver PCB in the selection console. If either illuminates,

replace the motor valve. If they do not illuminate, replace

PCB3.

133

Unknown gas

console type

The power supply control

board does not recognize

the gas console that

is installed or has not

received a CAN message.

1. Verify that the part numbers of PCB2 and PCB3 are

correct.

2. Verify that the power supply-to-gas console control cable

is not damaged and is properly connected to PCB3 and

the rear of the gas console.

3. Verify that the power supply-to-gas console power cable is

not damaged and is properly connected inside the power

supply and to the rear of the gas console.

4. Verify that D1 (+5 VDC) and D2 (+3.3 VDC) are

illuminated on PCB2 inside the gas console. These LEDs

indicate power to PCB2.

5. If power is present at PCB2 and PCB3 and both gas

console cables are good, then PCB2 or PCB3 has failed.

Use the CAN tester to verify which board needs to be

replaced.