Hypertherm HPR800XD Auto Gas Rev.2 User Manual

Page 358

Advertising
background image

Appendix B – CnC interfACe protoCol

b-24

HPR800XD Auto Gas –

806500

ID

Name

Description

156 Primary

356 Secondary CHOPPER 2 CURRENT AT INIT Chopper 2 current signal is active on power-up

157 Primary

357 Secondary CHOPPER 3 CURRENT AT INIT Chopper 3 current signal is active on power-up

158 Primary

358 Secondary CHOPPER 4 CURRENT AT INIT Chopper 4 current signal is active on power-up

159 Primary

359 Secondary MOTOR DRIVE FAULT

Motor drive board power module is indicating an alarm – this

can be comparable to “blowing a fuse” – does not necessarily

indicate a problem with the board.

160

HPR COOLER CAN FAULT

Communications between the control board and the pump/motor

drive board was interrupted for greater than 1 second.

161

MAXIMUM COOLANT FLOW

EXCEEDED

Coolant flow has exceeded 6.8 lpm (1.8 gpm) for a cooler,

8.52 lpm (2.25 gpm) for a chiller.

180

SELECTION CONSOLE CAN

TIMEOUT

Power supply has not received a CAN message from the

selection console within 1 second

181

METERING CONSOLE CAN

TIMEOUT

Power supply has not received a CAN message from the

metering console within 1 second

182

SECONDARY POWER SUPPLY

TIMEOUT

The secondary power supply fails before transmitting the error to

the primary power supply.

383

SECONDARY POWER SUPPLY

TIMEOUT

The secondary power supply is ready to provide current output

but does not receive the control signal from the primary power

supply.

Advertising