Gas requirements, Setting the supply regulators, Gas requirements -61 – Hypertherm HPR800XD Auto Gas Rev.2 User Manual

Page 101: Setting the supply regulators -61

Advertising
background image

InstallatIon

HPR800XD Auto Gas –

806500

3-61

gas requirements

The customer must furnish all gases and gas-supply regulators for the system. Use a high-quality, 2-stage pressure

regulator located within 3 m (10 ft) of the selection console. See gas regulators in this section for recommendations.

See the Specifications section for gas and flow specifications. See Supply gas hoses at the end of this section for

recommendations.

Setting the supply regulators

1. Turn OFF the power to the system. Set all gas

regulator pressures to 8 bar (115 psi).

2. Turn ON the power to the system using the remote

ON/OFF switch or the CNC.

3. Set to Test Preflow.

4. While gas is flowing adjust the supply regulator for the

shield gas to 8 bar (115 psi).

5. Turn OFF Test Preflow.

6. Set system to Test Cutflow.

7. While gas is flowing adjust the supply regulator for the

plasma gas to 8 bar (115 psi).

8. Turn OFF Test Cutflow.

caution:

gas supply pressures not within the specifications in Section 2 can cause

poor cut quality, poor consumable life and operational problems.

If the purity level of the gas is too low or if there are leaks in the supply

hoses or connections,

•   Cut speeds can decrease

•   Cut quality can deteriorate

•   Cutting thickness capability can decrease

•   Parts life can shorten

Removed note about needing nitrogen as a

purge gas.

Advertising