Multi-drop addressing, Serial commands, Format – Hypertherm HPR800XD Auto Gas Rev.2 User Manual

Page 339: Framing, Commands

Advertising
background image

Appendix B – CnC interfACe protoCol

HPR800XD Auto Gas –

806500

b-5

Multi-drop addressing

The power supply control has DIP switches to set the power supply ID.

DIP switches 2, 3, 4 are used to set the ID.

2

3

4

ID

Off

Off

Off

0

On Off Off 1

Off On Off 2

On On Off 3

Off Off On Reserved

On Off On Reserved

Off On On Reserved

On On On Reserved

Systems with ID 0 power-up with the serial interface enabled. Systems with any other ID power-up with the serial

interface disabled.

To implement the multi-drop interface, the CNC must send the SLEEP command (086) which will put all systems on

the line into sleep mode. The WAKE command (085) with specific system ID will wake the system that the CNC wants

to communicate with. Any command can now be sent to that power supply, while all other systems will ignore the

communications. When the CNC is finished communicating with that power supply the SLEEP command must be sent,

then the WAKE command is used to communicate with the next system.

Serial commands

Format

ASCII-based protocol

Baud 19200

8 Data bits

1 Stop bit

No parity

No flow control

Framing

> = Start of message

3 byte command ID

Data

2 byte checksum

< = End of message
Sample: >0011C2<

commands

Responses will echo the ID of the command, unless there is an error in the command.