ElEctRoMAgNEtIc coMPAtIbIlIty (EMc)

Introduction

Hypertherm’s CE-marked equipment is built in compliance with

standard EN60974-10. The equipment should be installed and used

in accordance with the information below to achieve electromagnetic

compatibility.

The limits required by EN60974-10 may not be adequate to completely

eliminate interference when the affected equipment is in close proximity

or has a high degree of sensitivity. In such cases it may be necessary to

use other measures to further reduce interference.

This cutting equipment is designed for use only in an industrial

environment.

Installation and use

The user is responsible for installing and using the plasma equipment

according to the manufacturer’s instructions.

If electromagnetic disturbances are detected then it shall be the

responsibility of the user to resolve the situation with the technical

assistance of the manufacturer. In some cases this remedial action

may be as simple as earthing the cutting circuit, see Earthing of

the workpiece. In other cases, it could involve constructing an

electromagnetic screen enclosing the power source and the work

complete with associated input filters. In all cases, electromagnetic

disturbances must be reduced to the point where they are no longer

troublesome.

Assessment of area

Before installing the equipment, the user shall make an assessment

of potential electromagnetic problems in the surrounding area. The

following shall be taken into account:

a.

Other supply cables, control cables, signaling and telephone

cables; above, below and adjacent to the cutting equipment.

b.

Radio and television transmitters and receivers.

c.

Computer and other control equipment.

d.

Safety critical equipment, for example guarding of industrial

equipment.

e.

Health of the people around, for example the use of

pacemakers and hearing aids.

f.

Equipment used for calibration or measurement.

g.

Immunity of other equipment in the environment. User shall

ensure that other equipment being used in the environment is

compatible. This may require additional protection measures.

h.

Time of day that cutting or other activities are to be carried out.

The size of the surrounding area to be considered will depend on the

structure of the building and other activities that are taking place. The

surrounding area may extend beyond the boundaries of the premises.

Methods of reducing emissions

Mains supply

Cutting equipment must be connected to the mains supply according to

the manufacturer’s recommendations. If interference occurs, it may be

necessary to take additional precautions such as filtering of the mains

supply.

Consideration should be given to shielding the supply cable of

permanently installed cutting equipment, in metallic conduit or

equivalent. Shielding should be electrically continuous throughout its

length. The shielding should be connected to the cutting mains supply

so that good electrical contact is maintained between the conduit and

the cutting power source enclosure.

Maintenance of cutting equipment

The cutting equipment must be routinely maintained according to

the manufacturer’s recommendations. All access and service doors

and covers should be closed and properly fastened when the cutting

equipment is in operation. The cutting equipment should not be

modified in any way, except as set forth in and in accordance with the

manufacturer’s written instructions. For example, the spark gaps of

arc striking and stabilizing devices should be adjusted and maintained

according to the manufacturer’s recommendations.

cutting cables

The cutting cables should be kept as short as possible and should be

positioned close together, running at or close to the floor level.

Equipotential bonding

Bonding of all metallic components in the cutting installation and

adjacent to it should be considered.

However, metallic components bonded to the workpiece will increase

the risk that the operator could receive a shock by touching these

metallic components and the electrode (nozzle for laser heads) at the

same time.

The operator should be insulated from all such bonded metallic

components.

ElEctRoMAgNEtIc coMPAtIbIlIty (EMc)

Compliance Information

EMc-1