Connect the power, Connect the power -56 – Hypertherm HPR800XD Auto Gas Rev.2 User Manual

Page 96

Advertising
background image

InstallatIon

3-56

HPR800XD Auto Gas –

806500

connect the power

1. Insert the power cable through the strain relief at the rear of the power supply.

2. Connect the ground lead (PE) to the GROUND terminal (

) of TB1 as shown below.

3. Connect the power leads to the terminals of TB1 as shown below.

4. Verify that the line disconnect switch is in the OFF position and remains in the OFF position for the remainder of the

installation of the system.

5. Connect the power cord leads to the line disconnect switch following national and local electrical codes.
North American wire colors

U = black

v = white

w = Red

(PE) Earth ground = green/yellow

European wire colors

U = black

v = blue

w = brown

(PE) Earth ground = green/yellow

Line

disconnect

switch

Power

cable

TB1

W
V

Ground

U

U

V

W

DANgER

ElEctRIc SHock cAN kIll

t

he line disconnect switch must be in the oFF position before making the power cable

connections. In the U.S., use a “lock-out/tag-out” procedure until installation is complete. In other

countries, follow appropriate national and local safety procedures.

Advertising