Aluminum, Plasma / air shield 400 a, Metric marking – Hypertherm HPR800XD Auto Gas Rev.2 User Manual

Page 209: English

Advertising
background image

OperatiOn

HPR800XD Auto Gas –

806500

4-103

Aluminum

N

2

Plasma / Air Shield

400 A

Select

Gases

Set

Preflow

Set

Cutflow

Material

thickness

Arc

Voltage

Torch-to-Work

Distance

Cutting

Speed

Initial Pierce

Height

Pierce Delay

Time

Plasma

gas

Shield

gas

Plasma

gas

Shield

gas

Plasma

gas

Shield

gas

mm

Volts

mm

mm/m

mm Factor % Seconds

N

2

Air

30

50

70

31

12

155

3.8

4480

12.5

330

0.4

15

159

3770

0.5

20

163

4.1

2740

18.0

440

0.6

25

169

1850

0.7

30

175

1410

Edge start

40

188

810

50

206

410

Metric

Marking

Select

Gases

Set

Preflow

Set

Cutflow

Material

thickness

Arc

Voltage

Torch-to-Work

Distance

Cutting

Speed

Initial Pierce

Height

Pierce Delay

Time

Plasma

gas

Shield

gas

Plasma

gas

Shield

gas

Plasma

gas

Shield

gas

in

Volts

in

ipm

in

Factor % Seconds

N

2

Air

30

50

70

31

1/2

155

0.15

170

0.5

330

0.4

5/8

159

140

0.5

3/4

163

0.16

115

0.7

440

0.6

1

169

70

0.7

1-1/4

177

50

Edge start

1-1/2

178

35

1-3/4

198

25

2

206

16

English

220707

220637

220709

220712

220405

220708

Select

Gases

Set

Preflow

Set

Cutflow

Amperage Torch-to-Work

Distance

Marking

Speed

Arc

Voltage

Amps

mm

in

mm/m

ipm

Volts

N

2

N

2

10

10

10

10

22

2.5

0.10

1270

50

94

Ar

N

2

30

10

30

10

24

3.0

0.12

2540

100

50

220571

Flow rates – lpm/scfh

N

2

Air

Preflow

42 / 90 146 / 310

Cutflow

68 / 144 103 / 219

Advertising