OperatiOn

HPR800XD Auto Gas –

806500

4-3

Daily start-up

Prior to start-up, ensure that your cutting environment and that your clothing meet the safety requirements outlined in the

Safety section of this manual.

Torch

Current ring

Electrode

Swirl ring

Nozzle

Shield

Shield cap

Nozzle retaining cap

check torch

DANgER

ElEctRIc SHock cAN kIll

before operating this system, you must read the Safety section thoroughly. turn oFF the power

supply’s main disconnect switch before proceeding with the following steps.

1. Turn main disconnect switch to the power supply OFF.

2. Remove the consumables from the torch and check for worn or damaged parts. Always place the consumables

on a clean, dry, oil-free surface after removing. Dirty consumables can cause the torch to malfunction.

• Refer to

Install and inspect consumables

later in this section for details and for parts inspection tables.

• Refer to the Cut charts to choose the correct consumables for your cutting needs.

3. Replace consumable parts. Refer to

Install and inspect consumables

later in this section for details.

4. Ensure that the torch is perpendicular to the workpiece.