Maintenance

HPR800XD Auto Gas –

806500

5-27

Error code troubleshooting – error code 181, 182, 298, and 383

Error code

number

Name

Description

corrective action

181

Metering

console CAN

time-out

Auto gas

only

The power supply did not

receive a CAN message

from the metering

console within 1 second.

1. Verify that the power supply-to-metering console

CONTROL and POWER cables are not damaged and are

properly connected to PCB3, and the rear of the metering

console.

2. Verify that D17 (+5 VDC) and D18 (+3.3 VDC) are

illuminated on PCB2 inside the metering console. These

LEDs indicate power to PCB2. Also verify that D26

(CAN – RX) and D27 (CAN – TX) are illuminated on

PCB2 inside the metering console. These LEDs indicate

communication between the metering console and the

power supply.

3. If power is present at PCB2 and PCB3 and both metering

console cables are good, then PCB2 or PCB3 has failed.

Use the CAN tester to verify which board needs to be

replaced.

4. Verify that the gas console control PCB and power

distribution PCBs are securely mounted to the chassis at

all four corners.

182

Secondary

power supply

time-out

HPR400XD

HPR800XD

only

The secondary power

supply fails before

transmitting the error to

the primary power supply.

1. The primary power supply to secondary power supply

CAN communication cable was disconnected after

power-up.

2. The cable has electrical interference (noise) or the cable

shielding has been compromised.

298

Secondary

power supply

phase loss at

initialization

HPR800XD

only

The system detected

incoming line voltage

during power-up, before

the contactor was

energized.

1. Verify phase-to-phase voltage to power supply.

2. Disconnect power to power supply, remove cover on

contactor and inspect contacts for excessive wear.

3. Inspect power cord, contactor, and input to chopper for

loose connections.

4. Inspect phase loss fuses on Power Distribution board.

Replace board if fuses are blown.

5. Perform phase loss test (see Maintenance section).

383

No ramp-up

message

HPR400XD

HPR800XD

only

The secondary power

supply is ready to provide

current output but does

not receive the control

signal from the primary

power supply.

1 Turn off the power to the system and then turn on the

power again.

2. The cable has electrical interference (noise) or the cable

shielding has been compromised.