Pump motor drive board pcb7, Pump motor drive board pcb7 -44 – Hypertherm HPR800XD Auto Gas Rev.2 User Manual

Page 258

Advertising
background image

Maintenance

5-44

HPR800XD Auto Gas –

806500

Pump motor drive board Pcb7

D1

D30

D32

D10

D31

TP3

TP10

TP4

TP2

TP1

TP6

TP12

TP5

D35

D36

14102

7

control Pcb test points

Test point

number Description

Test point

number Description

Test point

number Description

TP1

Analog ground

TP5

+ 5 V

TP9

Digital ground

TP2

Digital ground

TP6

A + 3.3 V

TP10

+ 3.3 V

TP3

Reset\

TP7

+ 3.3 V

TP11

SCIRXD

TP4

Reset

TP8

SCITXD

TP12

LINEFB +

control Pcb lED list

LED

Description

Status

D1

+ 15 V OK

On when +15 voltage is OK

D10

+ 5 V OK

On when +5 voltage is OK

D16

+ 3.3 V OK

On when +3.3 voltage is OK

D30

IPM temperature alarm output

Off when OK. On when there is a sustained over-current condition.

D31

Temperature

Off when OK. On when there is a temperature fault.

D32

IPM alarm output

Off when OK. On when there is an internal overtemp, over-current, or bad gate

supply-drive voltage.

D35

Pump motor drive OK

On when pump-motor-drive is OK

D36

Pump motor drive enable

On when enabled

Note: The inductor on the pump motor-drive board makes a noise during operation that has been

described as a “hum”, “sing”, and “click”. This is normal and can be disregarded.

Advertising