Command table (4 of 14) – Hypertherm HPR800XD Auto Gas Rev.2 User Manual

Page 343

Advertising
background image

Appendix B – CnC interfACe protoCol

HPR800XD Auto Gas –

806500

b-9

command table (4 of 14)

ID

command

System

Description

074 GET_IO_STATUS

Manual gas system

Auto gas system

Read the status of the I/O ports of the DSP. Refer to I/O

listing for description of each bit in Ports A-F.
Data:

None
Return value:

PA00000000 PB00000000 PC00000000 PD00000000

PE00000000 PF00000000

Ports A-F are returned space-delimited. The numbers are the

decimal representation of the binary value of the port. 1 = on,

0 = off.
Sample:

>0749B<

>074PA00000100 PB00000000 PC00010101

PD00100000 PE00010000 PF10000000B7<

078 SET_ALL_GAS_FLOWS

Auto gas system

Set all gas flow rates.
N

2

mix setpoint and Gas 2 mix setpoint are only applicable

when using a mixed plasma gas such as H35 – N

2

.

Otherwise, these 2 values should be set to 0.
A value of 0 for N

2

mix setpoint will cause the system to close

SV12, the solenoid valve for N

2

mixing. A value of 0 for Gas 2

Mix Setpoint will cause the system to close SV13 and open

SV14. This will cause the inlet gas to bypass motor valve 2

and pass directly to the outlet of the mixing console.
Data:

Space-delimited:

Plasma cutflow (0 –99 psi),

Plasma preflow (0 – 99 psi),

Shield cutflow (0 – 99 psi),

Shield preflow (0 – 99 psi),

N

2

mix setpoint (0 – 100 psi),

Gas2 mix setpoint (0 – 100 psi).
Return value:

1 = accepted, 0 = not accepted
Sample:

>07855 45 35 25 50 50AB<

>0781D0<