Maintenance

5-26

HPR800XD Auto Gas –

806500

Error code troubleshooting – error codes 160 to 180

Error code

number

Name

Description

corrective action

160

HPR cooler’s

CAN fault

HPR400XD

only

Communication between

the control board (PCB3

in the power supply) and

the cooler sensor board

(PCB1 in the cooler) was

interrupted for more than

1 second.

1. Verify that the cable connections from the power supply to

the cooler are good.

2. Verify that D1 (+ 5 VDC) and D2 (+3.3 VDC) are

illuminated on PCB1 inside the cooler.

3. Verify that the CAN bus LEDs, D7 and D8 are blinking.

161

Maximum

coolant flow

has been

exceeded

Coolant flow has

exceeded 6.8 lpm

(1.8 gpm) for a cooler,

8.52 lpm (2.25 gpm) for

a chiller.

1. Verify proper coolant flow.

2. Look for air bubbles in the coolant.

3. Verify that the coolant is mixed in the proper proportions.

180

Selection

console CAN

time-out

Auto gas

only

The power supply did not

receive a CAN message

from the selection

console within 1 second.

1. Verify that the power supply-to-selection console

CONTROL and POWER cables are not damaged and are

properly connected to PCB3, and the rear of the selection

console.

2. Verify that D17 (+5 VDC) and D18 (+3.3 VDC) are

illuminated on PCB2 inside the selection console. These

LEDs indicate power to PCB2. Also verify that D26

(CAN – RX) and D27 (CAN – TX) are illuminated on

PCB2 inside the selection console. These LEDs indicate

communication between the selection console and the

power supply.

3. If power is present at PCB2 and PCB3 and both selection

console cables are good, then PCB2 or PCB3 has failed.

Use the CAN tester to verify which board needs to be

replaced.

4. Verify that the gas console control PCB and power

distribution PCBs are securely mounted to the chassis at

all four corners.