Power supplies, Power supplies -5 – Hypertherm HPR800XD Auto Gas Rev.2 User Manual

Page 29

Advertising
background image

SpecificationS

HPR800XD Auto Gas –

806500

2-5

Power supplies

229 mm

9.00 in

1270 mm

50.00 in

1175 mm

46.25 in

870 mm

34.25 in

851 kg

1877 lb

general
Maximum OCV (U

0

)

360 VDC

Maximum output current (I

2

)

400 Amps

Output voltage (U

2

)

50 – 200 VDC

Duty cycle rating (X)

100% @ 80 kw, 40° C (104° F)

Ambient temperature/Duty cycle

Power supplies will operate between -10° C and +40° C

(+14° and 104° F)

Power factor (cosϕ)

0.98 @ 400 ADC output

Cooling

Forced air (Class F)

Insulation

Class H

Power supply

Ac

voltage

(U

1

)

Phase Frequency

(Hz)

Amperage

(I

1

)

Regulatory

approval

Power kvA

(+/- 10%)

(U

1

x I

1

x 1.73)

Primary Primary

with

Hypernet

Secondary

078578

078586

078594

200/208

3

50/60

262/252

CSA

90.6

078579

078587

078595

220

3

50/60

238

CSA

90.6

078580

078588

078596

240

3

60

219

CSA

90.6

078581

078589

078597

380*

3

50/60

138

CCC

90.6

078582

078590

078598

400

3

50/60

131

CE/GOST-R

90.6

078583

078591

078599

440

3

50/60

120

CSA

90.6

078584

078592

078600

480

3

60

110

CSA

90.6

078585

078593

078601

600

3

60

88

CSA

90.6

* The 380 volt CCC regulatory approval only applies to 50 Hz operation

Note: Each power

supply has

the same

dimensions and

weight

(each power supply has the following specifications)

Advertising