InstallatIon

HPR800XD Auto Gas –

806500

3-3

Upon receipt

• Verify that all system components on your order have been received. Contact your supplier if any items

are missing.

• Inspect the system components for any physical damage that may have occurred during shipping. If there is

evidence of damage, refer to Claims. All communications regarding claims must include the model number and

serial number located on the rear of the power supply.

claims

claims for damage during shipment – If your unit was damaged during shipment, you must file a claim with the

carrier. Hypertherm will furnish you with a copy of the bill of lading upon request. If you need additional assistance,

call Customer Service listed in the front of this manual, or your authorized Hypertherm distributor.
claims for defective or missing merchandise – If any of the merchandise is defective or missing, contact your

supplier. If you need additional assistance, call Customer Service listed in the front of this manual, or your authorized

Hypertherm distributor.

Installation requirements

All installation and service of the electrical and plumbing systems must conform to national and local

electrical and plumbing codes. this work should be performed only by qualified, licensed personnel.
Direct any technical questions to the nearest Hypertherm Technical Service Department listed in the front of this manual,

or your authorized Hypertherm distributor.

Noise levels

Acceptable noise levels as defined by national and local codes may be exceeded by this plasma system. Always

wear proper ear protection when cutting or gouging. Any noise measurements taken are dependant on the specific

environment in which the system is used. See also Noise can damage hearing in the Safety section of this manual.

Specific information by product can be found in the Hypertherm downloads library at:
https://www.hypertherm.com/Xnet/library/DocumentLibrary.jsp
Select the product you are looking for from the Product Type drop down menu, choose “Regulatory” from the Category

drop down menu, and choose “Acoustical Noise Data Sheets” from the Sub Category drop down menu. Hit Submit.

Placement of system components

• Place all system components in position prior to making electrical, gas, and interface connections. Use the

diagram in this section for component-placement guidelines.

• Ground all system components to earth. See Recommended grounding and shielding practices in this section

for details.

• To prevent leaks in the system, tighten all gas and water connections as shown below:

torque specifications

gas or water hose

size

kgf-cm

lbf-in

lbf-ft

Up to 10 mm (3/8 in)

8.6-9.8

75-85

6.25-7

12 mm (1/2 in)

41.5-55

360-480

30-40