Command table (9 of 14) – Hypertherm HPR800XD Auto Gas Rev.2 User Manual

Page 348

Advertising
background image

Appendix B – CnC interfACe protoCol

b-14

HPR800XD Auto Gas –

806500

command table (9 of 14)

ID

command

System

Description

102 SET_GAS_IO_FROM_PS

Manual gas system

Auto gas system

This command will allow the user to turn on or off each output

of the processor. After sending this command, the SYSTEM_

RESET command must be issued to restore the processor state.

The I/O are in the following order:
Note: Use caution when selecting gas valves to make

sure fuel and oxidizers are not mixed together

resulting in a combustible mixture.

Data:

1 = On, 0 = Off for each I/O point
Return value:

1 = accepted, 0 = not accepted
Manual gas console

Shield cutflow

(SV16)

Calibrate bypass

(SV13)

Plasma cutflow 1

(SV14)

Ramp-down valve

(SV20)

Shield preflow

(SV17)

Plasma preflow

(SV18)

Plasma cutflow 2

(SV19)

H35 plasma cutflow 2

(SV12)

Spare valve

(SV15)

O

2

shield cutflow

(SV4)

Air shield cutflow

(SV5)

N

2

shield cutflow

(SV6)

Air preflow

(SV7)

N

2

preflow

(SV8)

Air plasma cutflow 2

(SV9)

Air plasma cutflow 1

(SV1)

O

2

plasma cutflow 1

(SV2)

H35 plasma cutflow 1

(SV3)

O

2

plasma cutflow 2

(SV10)

N

2

plasma cutflow

(SV11)

Auto gas console

O

2

inlet

(SV1)

Air

inlet

(SV2)

Air inlet 2

(SV3)

H5

inlet

(SV4)

H35

inlet

(SV5)

F5

inlet

(SV6)

Spare out 1

(Spare)

Ramp-down valve

(SV16)

Non-XD = Spare out 2, XD = Ar inlet2 (SV15)

Gas 2 no mix

(SV14)

Gas 2 mix

(SV13)

N

2

mix

(SV12)

N

2

inlet 2

(SV11)

Air inlet 3

(SV10)

N

2

inlet

(SV9)

O

2

air inlet

(SV8)

Non-XD = CH4 inlet, XD = Ar inlet1 (SV7)
Sample:

>1021111111111111111111167<

>1021C4<