InstallatIon

HPR800XD Auto Gas –

806500

3-49

10. Connect the shield gas hose (blue).

7. Connect the plasma-gas vent hose (white).

Note: The connectors in steps

7–10 are push-to-connect

fittings.

To make a connection, push

the hose fitting into the

appropriate connector until

it stops, 13 mm (0.5 in.).

To disconnect a fitting, push

the connector-collar toward

the torch, and pull the hose

away from the torch.

connector-collar

8. Connect the coolant supply hose (green).

9. Connect the plasma gas hose (black).