Maintenance

HPR800XD Auto Gas –

806500

5-23

Error code troubleshooting – error codes 141 to 152, 346 to 351

Error code

number

Name

Description

corrective action

141

Pressure

transducer

2 or 7 error

Auto gas

only

Faulty transducer or

control board in the

metering console or the

selection console.

1. Verify that transducer P2 in the selection console is

working properly. Replace if necessary.

2. Verify that transducer P7 in the metering console is working

properly. Replace if necessary.

3. Verify that the control boards in the metering and selection

consoles are working properly. Replace if necessary.

142

Pressure

transducer

3 or 5 error

Auto gas

only

Faulty transducer or

control board in the

metering console or the

selection console.

1. Verify that transducer P3 in the selection console is

working properly. Replace if necessary.

2. Verify that transducer P5 in the metering console is working

properly. Replace if necessary.

3. Verify that the control boards in the metering and selection

consoles are working properly. Replace if necessary.

143

Pressure

transducer

4 or 6 error

Auto gas

only

Faulty transducer or

control board in the

metering console or the

selection console.

1. Verify that transducer P4 in the selection console is

working properly. Replace if necessary.

2. Verify that transducer P6 in the metering console is working

properly. Replace if necessary.

3. Verify that the control boards in the metering and selection

consoles are working properly. Replace if necessary.

144

Internal flash

error

Manual gas

only

Communication problem

to the flash chip on

the gas console control

board.

Replace the control board.

145

Internal flash

error

Auto gas

only

Communication problem

to the flash chip on

the selection console

control board.

Replace the control board.

146

Primary

346

Secondary

Chopper 3

overtemp at

power-up

HPR400XD

only

Chopper 3 is indicating

an overtemp at power-up.

1. Verify that the temperature sensor for the chopper has not

been bypassed

or that the wires to the temperature switch

are shorted out in the harness, or that the sensor is open.

2. If no jumper is present, the chopper is overheated and

needs time to cool to 83° C (181.4° F).

147

Primary

347

Secondary

Chopper 4

overtemp at

power-up

HPR400XD

only

Chopper 4 is indicating

an overtemp at power-up.

1. Verify that the temperature sensor for the chopper has not

been bypassed or that the wires to the temperature switch

are shorted out in the harness, or that the sensor is open.

2. If no jumper is present, the chopper is overheated and

needs time to cool to 83° C (181.4° F).

151

Primary

351

Secondary

Software fail

Software has detected

an incorrect state or

condition.

Replace power supply control board.

152

Internal flash

error

Communication problem

to the flash chip on

the power supply control

board.

Replace the control board.

Advertising