Examples of output circuits, Examples of output circuits -36 – Hypertherm HPR800XD Auto Gas Rev.2 User Manual

Page 76

Advertising
background image

InstallatIon

3-36

HPR800XD Auto Gas –

806500

Examples of output circuits

1. Logic interface, active-high

2. Logic interface, active-low

3. Relay interface

4. Do not use this configuration. Warranty will be void.

High-impedance (≤10 mA)

10K

(optional)

CNC/PLC

5 VDC-24 VDC

C

HPR

E

+

-

HPR

C

E

+

-

5 VDC-24 VDC

High-impedance (≤10 mA)

CNC/PLC

10K

(optional)

CNC/PLC

CNC +24 V

+24 VDC

CNC +24 V

HPR

C

E

+

-

Power

ground

High-current

contact closure

inputs (AC or DC)

°t

Any voltage

voIDS

wARRAN

ty

HPR

Install a
Jumper
108056

J304

C

E

+

-

External relay

24VDC low-power coil

≤10 mA or ≥2400 ohms

All relay coils require a freewheeling diode

across the relay coil