Maintenance

5-22

HPR800XD Auto Gas –

806500

Error code troubleshooting – error codes 134 to 140, 334 and 338

Error code

number

Name

Description

corrective action

134

Primary

334

Secondary

Chopper 1

overcurrent

Chopper 1 current

feedback has exceeded

160 amps.

1. Verify that the wiring between CS1 and PCB3 is correct

and not damaged.

2. Measure voltage across current sensor.

a) Red to black = +15 VDC, Green to black = -15 VDC,

white to black = 0 VDC at idle and varies with current

output (4 VDC = 100 amps).

b) If possible, take a voltage reading on current sensor

while trying to cut. Ratio is 4 VDC = 100 amps.

c) If the current sensor voltage is approximately 6.4 VDC

or greater at idle, replace the current sensor.

3. Remove connector JA.1 from the chopper and verify that

LED1 is extinguished.

a) If LED1 is extinguished with the connector removed,

then reconnect JA.1 and try to fire the torch. If the

chopper still goes into overcurrent, replace the chopper.

b) If the chopper does not go into overcurrent, replace

PCB3.

138

Primary

338

Secondary

Chopper 2

overcurrent

HPR260XD

HPR400XD

only

Chopper 2 current

feedback has exceeded

160 amps.

1. Verify that the wiring between CS2 and PCB3 is correct

and not damaged.

2. Measure voltage across current sensor.

a) Red to black = +15 VDC, Green to black = -15 VDC,

white to black = 0 VDC at idle and varies with current

output (4 VDC = 100 amps).

b) If possible, take a voltage reading on current sensor

while trying to cut. Ratio is 4 VDC = 100 amps.

c) If the current sensor voltage is approximately 6.4 VDC

or greater at idle, replace the current sensor.

3. Remove connector JB.1 from the chopper and verify that

LED1 is extinguished.

a) If LED1 is extinguished with the connector removed,

then reconnect JB.1 and try to fire the torch. If the

chopper still goes into overcurrent, replace the chopper.

b) If the chopper does not go into overcurrent, replace

PCB3.

139

Purge

time-out error

The purge cycle did

not complete within

3 minutes.

This is a warning for a possible gas restriction in the leads.

1. Verify that there are no restrictions in the plasma and

shield hoses.

2. Verify that the inlet gas pressures are set to the proper

levels.

140

Pressure

transducer

1or 8 error

Auto gas

only

Faulty transducer or

control board in the

metering console or the

selection console.

1. Verify that transducer P1 in the selection console is

working properly. Replace if necessary.

2. Verify that transducer P8 in the metering console is

working properly. Replace if necessary.

3. Verify that the control boards in the metering and selection

consoles are working properly. Replace if necessary.