Command table (10 of 14) – Hypertherm HPR800XD Auto Gas Rev.2 User Manual

Page 349

Advertising
background image

Appendix B – CnC interfACe protoCol

HPR800XD Auto Gas –

806500

b-15

command table (10 of 14)

ID

command

System

Description

114 READ_INPUTS

Manual gas system

Auto gas system

This command will return the status of inputs to the PC board.

Data:

None
Return value:

1 = on, 0 = off
Power Supply

Serial program

Plasma start

Hold ignition

Phase OK

Arc detect

Pierce complete

Corner current

Redundant start

Serial ID0

Serial ID1

Serial ID2

Dipswitch #1

Dipswitch #5

Dipswitch #6

Dipswitch #7

Dipswitch #8

Chopper A overcurrent

Chopper B overcurrent
Sample:

>11496<

>114000000000000000000F6<

117 READ_GAS_INPUTS_FROM_PS Manual gas system

Auto gas system

This command will allow the CNC to query the gas console I/O

by sending the command to the serial port on the power supply

control board.
Data:

None
Return value:

1 = on, 0 = off
Manual gas console

Error select

Status select

Test preflow

Test cutflow

Serial ID bit 0

Serial ID bit 1

Serial ID bit 2
Auto gas console

Metering dipswitch 2

Metering dipswitch 3

Metering dipswitch 4

Select dipswitch 1

Select dipswitch 2

Select dipswitch 3

Select dipswitch 4

Metering dipswitch 1
Sample:

>11799<

>1170000000E9<

Advertising