Appendix B – CnC interfACe protoCol

b-16

HPR800XD Auto Gas –

806500

ID

command

System

Description

121 LEAK_CHECK_MODE

Manual gas system

Auto gas system

This command will put the system into leak mode. There are

3 modes, mode #1 is the inlet leak check mode. This is used to

see if the inlet solenoids are allowing gas to pass through the valve

even when they are closed.
Mode #2 is the system leak check mode which will test for leaks

to atmosphere within the system. Mode #3 is the Burkert valve

flow test. For automatic gas consoles only.

For the inlet leak test, the system should have 0 psi on all gas

channels, and hold at this pressure.
For the system leak test, the system should charge all gas lines,

then hold the pressure.
The Burkert flow test checks for an expected PWM value for a set

pressure and does a gas ramp-down test.

NotE: this test is preformed using 130 amp o

2

/ Air

consumables and setting the 30 amp o

2

/ o

2

process

Each test takes about 40 seconds to complete.
This command will only be accepted when the power supply is in

the state IDLE2 (03).
After leak checking is complete the system must be set to mode 0.
An error code will reflect the state of the test. Using the GET_

LAST_ERROR command, you can get the result of the test.
12 = Test in progress

13 = Test passed

14 = Cut gas channel #1 failed

15 = Cut gas channel #2 failed

16 = Plasma ramp-down test failed (Burkert test only)

17 = Shield ramp-down test failed (Burkert test only)
Data:

Mode 0 = run

1 = Inlet leak check

2 = System leak check

3 = Burkert flow check

Return value:

Time for the test to run in seconds, 0 = not accepted
Sample:

>1211C5<

>12140F8< “40 second test”