Primary power supply to selection console cables, Selection console communication cable, Selection console power cable – Hypertherm HPR800XD Auto Gas Rev.2 User Manual
Page 70

InstallatIon
3-30
HPR800XD Auto Gas –
806500
Primary Power supply to selection console cables
Selection console communication cable
Selection console power cable
*
Cable numbers 123784 and 123785 are for use with systems that have the gas console mounted on the power supply
Part no.
length
Part no.
length
123784*
3 m (10 ft)
123841
20 m (65 ft)
123839
4.5 m (15 ft)
123737
25 m (82 ft)
123963
6 m (20 ft)
123738
35 m (115 ft)
123691
7.5 m (25 ft)
123739
45 m (150 ft)
123840
10 m (35 ft)
123842
60 m (200 ft)
123711
15 m (50 ft)
123843
75 m (250 ft)
Part no.
length
Part no.
length
123785*
3 m (10 ft)
123848
20 m (65 ft)
123846
4.5 m (15 ft)
123740
25 m (82 ft)
123964
6 m (20 ft)
123676
35 m (115 ft)
123674
7.5 m (25 ft)
123677
45 m (150 ft)
123847
10 m (35 ft)
123849
60 m (200 ft)
123675
15 m (50 ft)
123850
75 m (250 ft)
Cable signal list – primary power supply to gas console
Power supply end
gas console end
Pin No.
Description
Pin No.
1
120 VAC-hot
1
2
120 VAC-return
2
3
Ground
3
4
Not used
4
5
Not used
5
6
24 VAC-hot
6
7
24 VAC-return
7
10
11
End with sockets to
selection console
Cable signal list – primary power supply to selection console (9-pin DSUB connectors)
Power supply end
Selection console
end
Pin No. Wire color
Input/Output
Description
Pin No.
Input/Output
Function
2
Black
Input/Output
CAN L
2
Input/Output
CAN communication
3
Black
Input
CAN ground
3
Output
Power ground
7
Red
Input/Output
CAN H
7
Input/Output
CAN communication
9
Red
Output
Not used
9
Output
Not used