Appendix B – CnC interfACe protoCol

b-22

HPR800XD Auto Gas –

806500

ID

Name

Description

054

HIGH SHIELD GAS PRESSURE Gas pressure is over upper limit of 7.58 bar (110 psi).

055

MV 1 INLET PRESSURE

Motor valve 1 inlet pressure is less than 3.45 bar (50 psi) or

greater than 9.65 bar (140 psi).

056

MV 2 INLET PRESSURE

Motor valve 2 inlet pressure is less than 3.45 bar (50 psi) or

greater than 9.65 bar (140 psi).

057

CUT GAS 1 PRESSURE

In the selection console, cut gas 1 outlet pressure is less than

3.45 bar (50 psi) or greater than 9.65 bar (140 psi).

058

CUT GAS 2 PRESSURE

In the selection console, if cut gas 2 outlet pressure is less than

3.45 bar (50 psi) for non-mixing, or less than 1.38 bar (20 psi)

when mixing or greater than 9.65 bar (140 psi) for non-mixing

and mixing.

060

LOW COOLANT FLOW

Coolant flow is less than the required 2.3 lpm (0.6 gpm).

061

NO PLASMA GAS TYPE

Plasma gas has not been selected.

062

NO SHIELD GAS TYPE

Shield gas has not been selected, or system is in test mode.

065 Primary

265 Secondary CHOPPER1 OVERTEMP

Chopper #1 overheated.

066 Primary

266 Secondary CHOPPER2 OVERTEMP

Chopper #2 overheated.

067 Primary

267 Secondary MAGNETICS OVERTEMP

Transformer has overheated.

071

COOLANT OVERTEMP

Torch coolant has overheated.

072

AUTOMATIC GAS CONTROL

BOARD OVERTEMP

Control board has exceeded 90° C (194° F).

073 Primary

273 Secondary CHOPPER3 OVERTEMP

Chopper #3 overheated

074 Primary

274 Secondary CHOPPER4 OVERTEMP

Chopper #4 overheated

075 Primary

275 Secondary

CURRENT TOO LOW ON LEM

#3

A current less than 10 amps has been detected by current

sensor 3.

076 Primary

276 Secondary

CURRENT TOO LOW ON LEM

#4

A current less than 10 amps has been detected by current

sensor 4.

093

NO COOLANT FLOW

Coolant flow is less than 0.6 gpm.

095

CURRENT TOO HIGH ON LEM

#4

Current has exceeded 35 amps during the chopper test

099 Primary

299 Secondary CHOPPER1 OVERTEMP AT INIT Chopper #1 is indicating overtemp during power-up.

100 Primary

300 Secondary CHOPPER2 OVERTEMP AT INIT Chopper #2 is indicating overtemp during power-up.

101 Primary

301 Secondary

MAGNETICS OVERTEMP AT

INIT

Transformer is indicating overtemp during power-up.

102 Primary

302 Secondary OUTPUT CURRENT AT INIT

Chopper current signal is active on power-up.

103 Primary

303 Secondary

CURRENT TOO HIGH ON LEM

#1

A current greater than 35 amps has been detected by current

sensor 1.

104 Primary

304 Secondary

CURRENT TOO HIGH ON LEM

#2

A current greater than 35 amps has been detected by current

sensor 2.

105 Primary

305 Secondary

CURRENT TOO LOW ON LEM

#1

A current less than 10 amps has been detected by current

sensor 1.