Screening and shielding, Sc-2 safety and compliance – Hypertherm HPR800XD Auto Gas Rev.2 User Manual

Page 6

Advertising
background image

Sc-2

Safety and Compliance

ElEctRoMAgNEtIc coMPAtIbIlIty (EMc)

Earthing of the workpiece

Where the workpiece is not bonded to earth for electrical safety, nor

connected to earth because of its size and position, for example, ship’s

hull or building steel work, a connection bonding the workpiece to

earth may reduce emissions in some, but not all instances. Care should

be taken to prevent the earthing of the workpiece increasing the risk

of injury to users, or damage to other electrical equipment. Where

necessary, the connection of the workpiece to earth should be made by

a direct connection to the workpiece, but in some countries where direct

connection is not permitted, the bonding should be achieved by suitable

capacitances selected according to national regulations.

Note: The cutting circuit may or may not be earthed for safety reasons.

Changing the earthing arrangements should only be authorized by a

person who is competent to assess whether the changes will in crease

the risk of injury, for example, by allowing parallel cutting current return

paths which may damage the earth circuits of other equipment. Further

guidance is provided in IEC 60974-9, Arc Welding Equipment, Part 9:

Installation and Use.

Screening and shielding

Selective screening and shielding of other cables and equipment in

the surrounding area may alleviate problems of interference. Screening

of the entire plasma cutting installation may be considered for special

applications.

Advertising