Sequence of operation, Sequence of operation -5 – Hypertherm HPR800XD Auto Gas Rev.2 User Manual

Page 219

Advertising
background image

Maintenance

HPR800XD Auto Gas –

806500

5-5

Sequence of operation

1. Power-up – The system verifies that all of these signals are off at power-up

Coolant flow off

Chopper current off

Transfer off

Phase Loss off

Chopper 1 over-temp off

Magnetics over-temp off

Coolant over-temp off

Plasma start off

2. Purge – Air or N

2

gas flows through torch for 20 seconds

Coolant flow on

Primary contactor closes and the chopper performs a chopper test and a current sensor test

Secondary contactor closes and the system tests the secondary choppers and current sensors

Plasma start off

Both contactors remain closed in the next state

3. Idle

Gas pressure ok

Coolant flow on

Chopper current off

Line voltage ok

4. Preflow – 2 second flow of gas

Primary and secondary contactors are closed

5. Pilot Arc – Current flow between electrode and nozzle

Chopper, main contactor and pilot arc relay are on

High frequency present

Chopper current sensor = pilot arc current

6. Transfer – Pilot arc current sensed on the worklead
7. Ramp-up – Primary chopper current increases to set point and gas changes to cutflow

Coolant flow on

Gas pressure ok

Phase loss on

Line voltage ok

After the primary choppers reach maximum current (400 amps), the secondary choppers increase current

output (if necessary) to a final setpoint

8. Steady State – normal operating parameters

Coolant flow on

Gas pressure ok

Phase loss on

Chopper 1 over-temp off

Magnetics over-temp off

Coolant over-temp off

9. Ramp-down – Current and gas flow decreases after plasma start has been removed

Cutflow gas off

10. Auto Off – 10 second postflow

Main contactors off

Choppers off