Command table (1 of 14) – Hypertherm HPR800XD Auto Gas Rev.2 User Manual

Page 340

Advertising
background image

Appendix B – CnC interfACe protoCol

b-6

HPR800XD Auto Gas –

806500

command table (1 of 14)

ID

command

System

Description

000 HELLO

Manual gas system

Auto gas system

Establish communications with the plasma system. Use this command

to determine if the system is configured as an 800XD or 400XD. This

command will return “HPR800XD” in place of “HPR400XD” when the

secondary power supply is connected and the power is on.
Data:

None
Return value:

String identifying the system
Sample:

>00090<

>000HYPERFORMANCE130MANUALB5<

or

>000HYPERFORMANCE130AUTO30<

or

>000HYPERFORMANCE130AUTOMIX1E<

001 VERSION

Manual gas system

Auto gas system

Get the version of the power supply firmware.
Data:

None
Return value:

Power supply firmware then Gas console firmware, space-delimited
Sample:

>00191<

>001A.0 A.25< (power supply rev A, gas rev A)

002 GET_STATE

Manual gas system

Auto gas system

Get the current state of the plasma system.
Data:

None
Return value:

Status code (see table V)
Sample:

>00292<

>002000052< (status code 0)

003 LAST_ERROR

Manual gas system

Auto gas system

Get the last error that occurred at the system.
Data:

None
Return value:

Error code (see table IV)
Sample:

>00393<

>00301165B< (error code 116)

004 REMOTE_MODE

Manual gas system

Auto gas system

Switch system into remote mode, to allow remote control of the plasma

system.
Data:

None
Return value:

1 = accepted, 0 = not accepted
Sample:

>00494<

>0041C5<

Advertising