Connect the supply gases, Connect the supply gases -64 – Hypertherm HPR800XD Auto Gas Rev.2 User Manual

Page 104

Advertising
background image

InstallatIon

3-64

HPR800XD Auto Gas –

806500

connect the supply gases

Connect the supply gases to the selection console. Torch leads must be purged between gas changes.

caution:

Synthetic lubricants containing esters that are used in some air compressors

will damage polycarbonates used in the air regulator bowl.

Fitting

Size

N

2

/ Ar

5/8 – 18, RH, internal (inert gas) “B”

Air

9/16 – 18, JIC, no. 6

H35 / F5 / H5 9/16 – 18, LH, (fuel gas) “B”

O

2

9/16 – 18, RH, (oxygen) “B”

caution:

Replacing the fittings on the selection console may cause the internal valves

to malfunction, because particulates can migrate into the valves.