Torch lead test, Torch lead test -55, Warning – Hypertherm HPR800XD Auto Gas Rev.2 User Manual

Page 269

Advertising
background image

Maintenance

HPR800XD Auto Gas –

806500

5-55

torch lead test

1. Turn OFF all power to the system.
2. Locate the start-circuit assembly.

H8

WORK

H9

NOZZLE

H8

WORK

H9

NOZZLE

+

D1

D2

3. Install a temporary jumper wire

between H8 (work) and H9

(nozzle) on the start circuit

PCB1.

4. Locate the pilot arc relay (CR1) and remove the dust cover. Have a second person close the contact.

5. Measure the ohm value between the nozzle and the plate. The reading should be less than 3 ohms. A measurement

of greater than 3 ohms indicates a faulty connection between the torch and ignition console or between the ignition

console and the power supply.

6. Verify that the pilot arc wire on the torch lead is not damaged. If it is damaged replace the lead. If it is not damaged,

replace the torch head.

wARNINg

SHock HAzARD

Always use caution when servicing a power supply when plugged in and the covers are removed.

Dangerous voltages exist within the power supply which could cause injury or death.

Advertising