Command table (8 of 14) – Hypertherm HPR800XD Auto Gas Rev.2 User Manual

Page 347

Advertising
background image

Appendix B – CnC interfACe protoCol

HPR800XD Auto Gas –

806500

b-13

command table (8 of 14)

ID

command

System

Description

100 GET_CONTROL_DATA

Manual gas system

Auto gas system

Read internal control data:
Chopper A used in HPR130/HPR260

Chopper B used in HPR260
Return string is the same whether the system is an HPR130 or

HPR260. Chopper B data can be ignored for HPR130.
Chopper A temp (raw A/D, 0 - 1023),

Chopper B temp (raw A/D, 0 - 1023),

Line voltage (1/10 volts, 0 - 2400), 240.0 vac

Coolant flow (1/100 gpm, 0 - 440), 4.40 gpm

Coolant temp (raw A/D, 0 - 1023),

Transformer temp (raw A/D, 0 - 1023),

Chopper A current (0 – 130 amps),

Chopper B current (0 – 130 amps),

Work lead current (0 – 130/260 amps),

Chopper A setpoint (5 – 130 amps),

Chopper B setpoint (5 – 130 amps),

PWM chopper A (100% = 1070),

PWM chopper B (100% = 1070).
Data:

None
Return value:

Above info is space-delimited.
Sample:

>10091<

>100CAT0482 CBT0021 LVO0118 CFL0009 CTP0481

TTP0481 CAC0001 CBC0014 WLC0005 CAS0000 CBS0534

PWMA0000 PWMB00000B<

101 SET_IO_STATUS

Manual gas system

Auto gas system

This command will allow the user to turn on or off each output of

the processor. After sending this command, the SYSTEM_RESET

command must be issued to restore the processor state. The I/O

are in the following order:
Data:

1 = On, 0 = Off for each I/O point
Return value:

1 = accepted, 0 = not accepted
Power Supply

Pilot arc Relay

Marking surge relay

Pilot arc enable

Coolant pump motor

Soft-start enable

CNC error

CNC ramp-down error

Igniter

Contactor

CNC machine motion

CNC spare output

Spare output
Sample:

>101111111111111DD< = All outputs on

>1011C3<