HPR800XD Auto Gas –

806500

5-13

Error code troubleshooting – error codes 030 to 042, 231 to 234

Error code

number

Name

Description

corrective action

030

Gas system

error

Auto gas

only

A failure has occurred in

the gas system.

1. Verify that cable number 5 (power supply-to-gas console

control cable) is not damaged and is properly connected

to PCB3 and to the rear of the gas console.

2. Verify that cable number 6 (power supply-to-gas console

power cable) is not damaged and is properly connected

inside the power supply and to the rear of the gas

console.

3. Verify that D1 (+5 VDC) and D2 (+3.3 VDC) are

illuminated on PCB2 inside the gas console. These LEDs

indicate power to PCB2.

4. If power is present at PCB2 and PCB3 and both gas

console cables are good, then PCB2 or PCB3 has failed.

Use the CAN tester to verify which board needs to be

replaced.

031

Primary

231

Secondary

Start lost

Start signal was received

and then lost before an arc

was established.

1. If a mechanical relay is being used to provide the HPR

with a start signal, this relay is either bouncing when

activated or the contacts are faulty. Replace the relay.

2. Inspect interface cable for damage; faulty crimps, or poor

electrical connections.

3. If interface cable is good and a relay is not driving the

start input, the CNC is dropping the start signal before a

steady state arc has been established.

032

Hold timeout Hold signal was active for

longer than 60 seconds.

1. Check the interface cable for damage. The hold wires may

be short-circuiting inside.

2. The CNC is maintaining this input, it could be waiting for

an IHS complete input from another torch.

3. If CNC interface cable is good and it is a 1-torch system,

change PCB3.

033

Precharge

time-out

Auto gas

only

Selection console was not

able to charge the lines to

the correct value.

This is a warning for a possible gas restriction in the leads.

Verify that there are no restrictions in the plasma and shield

hoses, or low inlet-gas pressure.

034

Primary

234

Secondary

Lost current

Chopper 4

HPR400XD

only

Lost the current signal from

Chopper 4 after transfer.

1. Verify that the consumable parts are in good condition.

2. Verify proper cut-flow gas settings.

3. Verify pierce delay time.

4. Verify arc did not lose contact with plate while cutting

(hole cutting, scrap cutting, etc).

042

Low nitrogen

(N

2

) gas

pressure

Nitrogen gas pressure

under lower limit of:

2.07 bar (30 psi) – cutting

0.34 bar (5 psi) – marking

During N

2

purge, when

changing between a fuel

gas process and an oxidizer

process.

1. Verify that the nitrogen supply is turned on and inspect gas

supply pressure and volume of gas remaining in supply

tanks.

2. Verify that the gas regulator is set to 8.27 bar (120 psi).

See Setting the supply regulators (Installation section).