Cnc controller requirements, Cnc controller requirements -5 – Hypertherm HPR800XD Auto Gas Rev.2 User Manual

Page 111

Advertising
background image

OperatiOn

HPR800XD Auto Gas –

806500

4-5

cNc controller requirements

Note: See appendix B, CNC interface protocol, for more detailed information.

base required elements

The following elements should be able to be displayed and adjusted on the CNC for setup and basic system

information. The plasma system needs this group for basic setup and operation capability.
1. Remote ON/OFF

2. Ability to display and adjust the basic plasma process set-points (command ID no. 95)

a. Current set point

b. Plasma preflow

c. Plasma cutflow

d. Shield preflow

e. Shield cutflow

f. Plasma gas type

g. Shield gas type

h. Gas mixing set-points

3. Display basic system information

a. System error code

b. Gas and PS firmware version

4. Manual pump control

Required real time elements

Note: These elements are not available for the secondary power supply.

The following elements should be able to be displayed in real time while cutting. This is necessary for trouble shooting

and diagnostic purposes.
5. Display line voltage

6. Display chopper current

7. Display work lead current

8. Display system status code

9. Display chopper temperature

10. Display transformer temperature

11. Display coolant temperature

12. Display coolant flow

13. Display pressure transducers

Required diagnostic elements

These elements provide additional diagnostic capability to the system for troubleshooting gas-delivery problems. The

CNC should be capable of executing these commands and displaying the relevant information for the respective test

according to the serial protocol guidelines.
14. Test preflow gases

15. Test cutflow gases

16. Inlet leak test

17. System leak test

18. System flow test