Coolant system servicing, Draining the coolant system, Coolant system servicing -34 – Hypertherm HPR800XD Auto Gas Rev.2 User Manual

Page 248: Draining the coolant system -34

Advertising
background image

Maintenance

5-34

HPR800XD Auto Gas –

806500

coolant system servicing

Draining the coolant system

1. Turn OFF all power to the plasma system and the chiller.

2. Drain the coolant from the chiller. A 3/4 inch female NPT connection is located at the bottom of the sight glass for

draining the coolant from the chiller reservoir. The connection should be piped to a drain or receptacle positioned

lower than the bottom of the reservoir. If a receptacle is used it must be large enough to hold all the coolant in the

chiller 60.5 lpm (16 gal).

3. Remove the return coolant hose (red tape on the hose) from the rear of the chiller and put it in a 20 liter (5 gallon)

container.

Sight glass

3/4 inch female NPT

connection

Return

coolant hose

Advertising