Error codes are displayed on the CNC screen. The diagnostic screen shown below is for reference. The screens you

work with may be different, but should include the functions described in the Operation section of this manual.

Error codes

Errors that can be generated by either the primary power supply or the secondary power supply will have 2 entries in the

error code number column. The first number will represent the primary power supply and the second will represent the

secondary power supply. The secondary error code entry equals the primary error code number plus 200.

See the example below:

Error code

number

Name

Description

corrective action

102

Primary

302

Secondary

Chopper 1

current at

power-up

Chopper 1 current signal

is active at power-up

See wiring diagrams in section 7
1. Verify that the voltage at CS1 is correct.

2. Verify that the wiring between CS1 and PCB3 is correct and

not damaged.

3. Swap CS1 with CS2. If the error code changes to 156,

replace the original CS1.