Stainless steel, F5 plasma / n, Shield 80 a – Hypertherm HPR800XD Auto Gas Rev.2 User Manual

Page 170: Marking, Metric english

Advertising
background image

OperatiOn

4-64

HPR800XD Auto Gas –

806500

Stainless steel

F5 Plasma / N

2

Shield

80 A

220338

220747

220339

220755

220179

220337

Marking

Flow rates – lpm/scfh

F5

N

2

Preflow

0 / 0

67 / 142

Cutflow

31 / 65 87 / 185

Select

Gases

Set

Preflow

Set

Cutflow

Amperage Torch-to-Work

Distance

Marking

Speed

Arc

Voltage

Amps

mm

in

mm/m

ipm

Volts

N

2

N

2

10

10

10

10

15

2.5

0.10

6350

250

95

Ar

N

2

50

10

50

10

12

3.0

0.12

2540

100

60

220340

Metric

English

Select

Gases

Set

Preflow

Set

Cutflow

Material

thickness

Arc

Voltage

Torch-to-Work

Distance

Cutting

Speed

Initial Pierce

Height

Pierce Delay

Time

Plasma

gas

Shield

gas

Plasma

gas

Shield

gas

Plasma

gas

Shield

gas

mm

Volts

mm

mm/m

mm Factor % Seconds

F5

N

2

33

23

65

60

4

108

3.0

2180

4.5

150

0.2

5

110

2.7

1700

4.1

0.3

6

112

2.5

1225

3.8

8

116

3.0

895

4.5

0.4

10

120

560

0.5

Select

Gases

Set

Preflow

Set

Cutflow

Material

thickness

Arc

Voltage

Torch-to-Work

Distance

Cutting

Speed

Initial Pierce

Height

Pierce Delay

Time

Plasma

gas

Shield

gas

Plasma

gas

Shield

gas

Plasma

gas

Shield

gas

in

Volts

in

ipm

in

Factor % Seconds

F5

N

2

33

23

65

60

0.135

108

0.12

105

0.18

150

0.2

3/16

110

0.11

60

0.17

0.3

1/4

112

0.10

45

0.15

5/16

116

0.12

35

0.18

0.4

3/8

120

25

0.5

Advertising