Hypertherm HPR800XD Auto Gas Rev.2 User Manual

Page 124

Advertising
background image

OperatiOn

4-18

HPR800XD Auto Gas –

806500

Inspect

look for

Action

Swirl ring

general:

Chips or cracks
Blocked gas holes
Dirt or debris
o-rings:

Damage
Lubricant

Replace swirl ring
Replace swirl ring
Clean and check for damage; replace when damaged

Replace swirl ring
Apply a thin film of silicone lubricant if the o-rings

are dry

Electrode

Always replace the nozzle and

electrode as a set.

center surface:

Emitter wear – a pit forms as

the emitter wears.

o-rings:

Damage

Lubricant

In general, replace the electrode when the pit depth is

1 mm (0.04 in.) or greater. For the 400 amp mild steel

electrode and all SilverPlus electrodes, replace the

electrode when the pit depth is 1.5 mm (0.06 in.) or

greater. See Electrode pit depth gage below.

Replace electrode

Apply a thin film of silicone lubricant if the o-rings

are dry

Emitter

10

0

20

40

30

4

0

2

3

1

80

60

70

50

90

Electrode pit depth gage (004147)