Maintenance

5-54

HPR800XD Auto Gas –

806500

Phase-loss detection test

1. Turn OFF all power to the system and remove the cover from CON1.

2. Inspect the condition of the 3 contacts for excessive wear. If one or more of the contacts are worn excessively,

replace CON1 and restart the system. If the error remains, perform the following steps.

3. Test the fuses F5, F6, and F7 on the power

distribution board (PCB2). If any of the fuses

are blown, replace PCB2.

4. Remove J2.8 from PCB2 and place a jumper between pins 1 and 2 on the cable connector.

a. Make a test cut. If the phase-loss error continues, verify wiring between J2.8 on PCB2 and J3.302 on PCB3 by

verifying the continuity between:

– J2.8 pin1 to J3.302 pin14

– J2.8 pin2 to J3.302 pin15.

b. If the wiring is OK, replace PCB3. If any wiring is damaged, repair or replace any damaged wires.
c. If the phase-loss error goes away while the jumper is on J2.8, make another cut and measure the phase-to-

phase voltage across the fuses F5, F6, and F7. The voltage should be 220 VAC +/-15%. If 1 of the 3 voltage

readings is less than 187 VAC, check the contacts to the contactor, and check for loose connections between

the power cord, contactor, power transformer, and the chopper.