V T 1 0 0 I n t e r f a c e

4-19

Figure 4.16

Span Endpoint Maintenance Screen

The Span Endpoint Maintenance parameters are described below.

L oop b ack Typ e

Specifies loopbacks for the associated segment endpoint.

Values: No Loopback, Normal Loopback
Default: No Loopback

L o op b ack T im eo u t

Specifies the timeout value in minutes for loopbacks initiated at segments
endpoints contained in the associated unit. A value of 0 disables the timeout.

T ip R in g

Indicates the state of the tip/ring pair at the associated segment endpoint.

P ow er S ou rce

Indicates the DC power source being used by the associated unit.

R estart E n d p oin t

Enables the manager to trigger a soft restart of the SHDSL line at the
associated segment endpoint. The manager may only set this object to the
“restart” value to initiate a restart. The agent will perform a restart after
approximately 5 seconds, and restore the object to the “ready” state.

Values: Ready, Restart
Default: Ready

Selecting the “Performance” prompt on the Span Endpoint Details screen will
display the screen shown in Figure 4.17.